logo
calendar13 Fevral 2021
view28
Main language:Uzbek

INVESTIGATION OF WALL’S OPTIMUM INSULATION POSITION FROM MAXIMUM TIME LAG AND MINIMUM DECREMENT FACTOR POINT OF VIEW IN PASSIVE SYSTEMS SOLAR HEATING

Field of Science:
pdf

file.pdf

PDF

ARTICLE ANNOTATION

quote
In this study investigated definition of wall’s optimum insulation position from maximum time lag and minimum decrement factor point of view in passive systems solar heating.

AUTHORS

Tags

# солнечная энергия# solar energy# теплопередача# heat transfer# қуёш энергияси# иссиқлик узатиш# запаздывание во времени# коэффициента затухание температу# температура максимал қийматининг# температура тебранишларининг сўн# time lag# decrement factor# passive system

OTHER ARTICLES IN THIS JOURNAL

Rate Article

0
0 ratings
5
4
3
2
1

Article Identifiers

References

1. Третье национальное сообщение Республики Узбекистан по рамочной конвенции ООН об изменении климата. Центр гидрометеорологической службы при Кабинете Министров Республики Узбекистан. – Ташкент, 2016, -220с.

2. Авезов Р.Р., Орлов А.Ю. Солнечные системы отопления и горячего водоснабжения. -Ташкент.: Фан, 1988. -288с.

3. Duffie J., Beckman W. “Solar engineering of thermal processes”, New York, Wiley, p. 928, 2013.

4. Al-Sanea S.A., Zedan M.F., Al-Hussain S.N. Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential / Applied Energy 89 (2012) 430–442.

5. Asan H., Sancaktar Y.S. Effects of Wall’s thermophysical properties on time lag and decrement factor / Energy and Buildings 28 (1998) 159-166.

6. Rossia M., Rocco V. M. External walls design: The role of periodic thermal transmittance and internalareal heat capacity / Energy and Buildings 68 (2014) 732–740.

7. Aste N., Leonforte F., Manfren M., Mazzon M. Thermal inertia and energy efficiency – Parametric simulation assessment on a calibrated case study / Applied Energy 145 (2015) 111–123.

8. Asan H. Investigation of wall’s optimum insulation position from maximum time lag and minimum decrement factor point of view / Energy and Buildings 32, 2000. 197–203.

9. Kontoleon K.J., Theodosiou Th.G., Tsikaloudaki K.G. The influence of concrete density and conductivity on walls’ thermal inertia parameters under a variety of masonry and insulation placements / Applied Energy 112 (2013) 325–337.

10. Ҫengel Y.A., Ghajar A.J. Heat and Mass Transfer: Fundamentals & Applications / New York, McGraw-Hill, p. 1208, 2015.

11. http://thermalinfo.ru/svojstva-materialov/strojmaterialy/teploprovodnost-stroitelnyh-materialov-ih-plotnost-i-teploemkost