logo
calendar29 Noyabr 2019
view36
Main language:Uzbek

ЭЛЕКТР ТАЪМИНОТИ ТИЗИМИДА РЕАКТИВ ҚУВВАТ КОМПЕНСАЦИЯСИ

Field of Science:
pdf

5de0ba4e4d06f.pdf

PDF

ARTICLE ANNOTATION

quote
In this article are viewed problems of optimization regimes of electrical supply systems and decreasing power losses for declining reactive power flow. Analyzed power losses in power transmission line of 0,4/10 kV and studied methods and means of them. Also, it is given the advantages of using a capacitor bank as compensation equipment equipped with induction motor in the pump station.