33

Hozirgi vaqtda Respublikamizda kommunal-maishiy va ijtimoiy obyektlar, aholi xonadonlarining issiqlik va issiq suv ta’minoti tizimlarida an’anaviy energiya resurslarini tejash, qayta tiklanuvchi energiya manbalaridan foydalanishni rivojlantirish muammolariga alohida e’tibor qaratilmoqda. Qashqadaryo viloyati iqlim xususiyatlarini hisobga olgan holda, isitish maydoni 144 m² yuzaga ega bo‘lgan qishloq uylarining issiqlik yuklamalarini hisoblash ishlari amalga oshirilgan.

Usul va materiallar. Namunaviy qishloq uylarining issiqlik, sovutish va issiq suv taminoti tizimlari issiqlik yuklamalarini issiqlik-texnik, gradus-sutkalar va eksperimental usullardan foydalanib hisoblangan.

Natijalar. Isitish maydoni 144 м2, isitish hajmi 432 m3 bolgan namunaviy qishloq uyining issiqlik yuklamasi 13,8÷14,0 kVtsovutish tizimida issiqlik yuklamasi 10,1 kVt va issiq suv taminoti tizimidagi issiqlik yuklamasi 1,3 kVt ekanligi aniqlangan. 2023 va 2024 yil isitish mavsumida har oyning 18-sanasida otkazilgan tajribaviy tadqiqot natijalari asosida isitish maydoni 144 м2 bolgan qishloq uyining issiqlik yuklamalar grafiklari olingan (1 va 2 rasm).

  • Read count 33
  • Date of publication 27-09-2024
  • Main LanguageO'zbek
  • Pages177-183
Русский

В настоящее время в нашей Республике уделяется особое внимание вопросам экономии традиционных энергетических ресурсов в системах теплоснабжения и горячего водоснабжения коммунально-бытовых и социальных объектов, а также жилых домов и развитию использования возобновляемых источников энергии (ВИЭ). В данной работе с учетом климатических особенностей Кашкадарьинской области были проведены расчеты тепловых нагрузок и теплоэнергетических характеристик для типовых сельских домов с площадью отопления 144 м².

Методы и материалы. Тепловые нагрузки систем отопления, охлаждения и горячего водоснабжения сельских домов рассчитаны с использованием методов укрупненных показателей гродусо-суток  отопительного периода (ГСОП) и экспериментальных измерений.

Результаты. Определены, что тепловая нагрузка сельского дома с отапливаемой площадью 144 м² и объемом 432 м³ составляет 13,8÷14,0 кВт, тепловая нагрузка в системе вентиляции — 10,1 кВт, а в системе горячего водоснабжения — 1,3 кВт. На основе результатов экспериментальных исследований, проводимых 18-го числа каждого месяца в отопительном сезоне 2023 и 2024 годов, были получены графики тепловых нагрузок для сельского дома с отапливаемой площадью 144 м² (рисунки 1 и 2).

Ўзбек

Hozirgi vaqtda Respublikamizda kommunal-maishiy va ijtimoiy obyektlar, aholi xonadonlarining issiqlik va issiq suv ta’minoti tizimlarida an’anaviy energiya resurslarini tejash, qayta tiklanuvchi energiya manbalaridan foydalanishni rivojlantirish muammolariga alohida e’tibor qaratilmoqda. Qashqadaryo viloyati iqlim xususiyatlarini hisobga olgan holda, isitish maydoni 144 m² yuzaga ega bo‘lgan qishloq uylarining issiqlik yuklamalarini hisoblash ishlari amalga oshirilgan.

Usul va materiallar. Namunaviy qishloq uylarining issiqlik, sovutish va issiq suv taminoti tizimlari issiqlik yuklamalarini issiqlik-texnik, gradus-sutkalar va eksperimental usullardan foydalanib hisoblangan.

Natijalar. Isitish maydoni 144 м2, isitish hajmi 432 m3 bolgan namunaviy qishloq uyining issiqlik yuklamasi 13,8÷14,0 kVtsovutish tizimida issiqlik yuklamasi 10,1 kVt va issiq suv taminoti tizimidagi issiqlik yuklamasi 1,3 kVt ekanligi aniqlangan. 2023 va 2024 yil isitish mavsumida har oyning 18-sanasida otkazilgan tajribaviy tadqiqot natijalari asosida isitish maydoni 144 м2 bolgan qishloq uyining issiqlik yuklamalar grafiklari olingan (1 va 2 rasm).

English

At present, in our Republic, special attention is paid to the issues of saving traditional energy resources in the systems of heat supply and hot water supply of municipal and social facilities, as well as residential buildings, and the development of the use of renewable energy sources. In this work, taking into account the climatic features of the Kashkadarya region, calculations of heat loads and heat energy characteristics for rural houses with a heating area of 144 m² were carried out.

Methods and materials. Heat loads of heating, cooling, and hot water supply systems of rural houses are calculated using methods enhanced by the indicator of the heating period of the GSOP, degree-days, and experimental measurements.

Results. It was determined that the heat load of a rural house with a heated area of 144 m² and a volume of 432 m³ is 13.8÷14,0 kW, the heat load in the ventilation system is 10.1 kW, and in the hot water supply system - 1.3 kW. Based on the results of experimental studies conducted on the 18th of each month in the heating season of 2023 and 2024, heat load graphs were obtained for a rural house with a heated area of ​​144 m² (Figures 1 and 2).

Name of reference
1 1. Ўзбекистон Республикаси Президентининг 2023 йил 16 февралдаги «2023 йилда қайта тикланувчи энергия манбаларини ва энергия тежовчи қурилмаларини жорий этишни жадаллаштириш чора-тадбирлари тўғрисида»ги ПҚ-57 сонли қарори.
2 2. Ўзбекистон Республикаси Президентининг 2022 йил 28 январдаги «2022-2026 йилларга мўлжалланган Янги Ўзбекистоннинг тараққиёт стратегияси тўғрисида» ги ПФ-60-сонли фармони.
3 3. Uzakov G., Khamraev S., Khuzhakulov S. Rural house heat supply system based on solar energy. IOP Conference Series: Materials Science and Engineering, 2021, 1030(1), 012167
4 4. Узаков Г. Н., Базаров О. Ш., Давланов Х. А., Тошмаматов Б. Научно-инновационные разработки Каршинского инженерно-экономического института по использованию возобновляемых источников энергии Беларусь-Узбекистан: формирование рынка инновационной продукции Сборник материалов научно практической конференции (Минск, 14–15 марта 2023 г.), стр. 353-356.
5 5. Узаков Г.Н., Давланов Х.А., Тошмаматов Б.М. Энергоэффективные системы и технологии с использованием альтернативных источников энергии //Альтернативная энергетика. 2021. Т. 1. С. 7-19.
6 6. Узаков Г.Н., Алиярова Л.А., Ибрагимов У.Х., Тошмаматов Б.М. Исследование комбинированного водовоздушного солнечного коллектора при ламинарном гидродинамическом режиме//Альтернативная энергетика. 2021. Т. 1. С. 33-40.
7 7. Узаков Г.Н., Давланов Х.А., Тошмаматов Б.М. Анализ гибридных систем отопления жилых зданий, использующие ВИЭ//Альтернативная энергетика. Научно-технический журнал. 2023. Т. 8. № 1. С. 9-15.
8 8. Узаков Г.Н., Давланов Х.А., Камoлов Б.И., Тошмаматов Б.М. Интегрированные автономные системы энергоснабжения объектов, расположенных в сельской местности//Алтернативная энергетика. Научно-технический журнал. №2, 03.07.2023-г. Стр. 9-14.
9 9. Zakhidov R.A., Tajiyev U.A., Kiseleva E.I., Saliev G.S., Gorobtsov S.I. On the Possibility of Sustainable Energy and Water Supply of Low-Rise Residential Buildings Located in Areas with an Arid Climate using Combined Wind and Solar Photovoltaic Power Complexes of Low Power. Applied Solar Energy (English translation of Geliotekhnika) this link is disabled, 2022, 58(1), pp. 159–164.
10 10. КМК. 2.01.18-2018.
11 11. Исаканов Е.М., Шыныбай Ж.С. Моделирование теплонасосных систем теплохлодоснабжения сельских домов // Исследования, результаты. №4 (76) 2017, С. 508-512.
12 12. Пилипенко Н.В. Тепловые потери и энергетическая эффективность зданий и сооружении. С. Петербург, 2016.48 с.
13 13. Каваленко Е.В., Тягунов М.Г. Гибридные энергетические комплексы с когенерацией в изолированных энергетических системах//Альтернативная энергетика и экология. №10-11, 2015, 167-177 с.
14 14. Ливчак В.И. Градусо-сутки отопительного периода как инструмент сравнения уровня энергоэффективности зданий в России и в других странах//Энергосбережение. №6, 2015 г. С. 20-25.
15 15. Беркова Е.А., Ример А. Обоснование оптимального варианта теплоснабжения автономных объектов с использованием тепловых насосов// В сборнике: 66-я Международная научная конференция. Астрахань, 2022. С. 399-403.
Waiting