58

Maqolada kobinatsiyalashgan bug‘-gaz qurilmali issiqlik elektr
stansiyalarining ishlash jarayonida termodinamik tavsifnomalar, ish rejimlari o‘zgarishining
foydali ish koeffitsiyenti, energetik va eksergetik samaradorlik ko‘rsatkichlariga ta’sirini
modellashtirish masalalari bo‘yicha olib borilgan ilmiy izlanishlar natijalari tahlil qilingan hamda
ikki konturli qozon-utilizatoriga ega bug‘-gaz qurilmasida qo‘shimcha yoqilg‘i yoqish
jarayonlarining matematik modeli taklif etilgan.

  • Ссылка в интернете
  • DOI
  • Дата создание в систему UzSCI 16-09-2024
  • Количество прочтений 58
  • Дата публикации 26-09-2023
  • Язык статьиO'zbek
  • Страницы71-77
Ўзбек

Maqolada kobinatsiyalashgan bug‘-gaz qurilmali issiqlik elektr
stansiyalarining ishlash jarayonida termodinamik tavsifnomalar, ish rejimlari o‘zgarishining
foydali ish koeffitsiyenti, energetik va eksergetik samaradorlik ko‘rsatkichlariga ta’sirini
modellashtirish masalalari bo‘yicha olib borilgan ilmiy izlanishlar natijalari tahlil qilingan hamda
ikki konturli qozon-utilizatoriga ega bug‘-gaz qurilmasida qo‘shimcha yoqilg‘i yoqish
jarayonlarining matematik modeli taklif etilgan.

Имя автора Должность Наименование организации
1 Xujakulov S.M. t.f.f.d., dotsent QarMII
Название ссылки
1 Afshin Abdollahian, Mehran Ameri. Effect of supplementary firing on the performance of a combined cycle power plant. Applied Thermal Engineering 193 (2021) 117049. https://doi.org/10.1016/j.applthermaleng.2021.117049.
2 M. Ameri, P. Ahmadi, S. Khanmohammadi, Exergy analysis of a 420MW combined cycle power plant, Int. J. Energy Res. 32 (2) (2008) 175–183.
3 D. Ghorbanzadeh, B. Ghashami, S. Masoudi, S.H. Khanmohammadi, Exergy Analysis of NekaIran Heat Recovery Steam Generator at Different Ambient Temperatures, in: Proc. of the 3rd IASME/WSEAS Int. Conf. on Energy, Environment, Ecosystems and Sustainable Development, AgiosNikolaos, Greece, July (24–26) 2007.
4 Z. Aminov, N. Nakagoshi, T.D. Xuan, O. Higashi, K. Alikulov, Evaluation of the energy efficiency of combined cycle gas turbine. Casestudy of Tashkent thermal power plant, Uzbekistan, Appl. Therm. Eng. 103 (2016) 501–509.
5 F. Cziesla, G. Tsatsaronis, Z. Gao, Avoidable thermodynamic inefficiencies and costs in an externally fired combined cycle power plant, Energy 31 (10-11) (2006) 1472–1489.
6 X. Shi, B. Agnew, D. Che, J. Gao, Performance enhancement of conventional combined cycle power plant by inlet air cooling, inter-cooling and LNG cold energy utilization, Appl. Therm. Eng. 30 (2010) 2003-2010.
7 F. Alobaid, Start-up improvement of a supplementary-fired large combined-cycle power plant, J. Process Control 64 (2018) 71–88.
8 P.J. Dechamps, N. Pirard, Ph Mathieu, Part-load operation of combined cycle plants with and without supplementary firing, J. Eng. Gas Turb. Power 117/475 (1995).
9 B.V. Reddy, K. Mohamed, Exergy analysis of a natural gas fired combined cycle power generation unit, Int. J. Energy Res. 4 (2) (2007) 180, https://doi.org/10.1504/IJEX.2007.012065.
10 A. Almutairi, P. Pilidis, N. Al-Mutawa, Energetic and exergetic analysis of combined cycle power plant: Part-1 operation and performance, Energies 8 (12) (2015) 14118–14135.
11 H. Sreedharan, J.R. Reshma, J.K. Jacob, V.V. Sivakumar, Energy and exergy analysis on 350MW combined cycle power plant, Eur. J. Technol. Des. 12 (2016) 2.
12 M.A. Javadi, H. Ghomashi, Thermodynamics analysis and optimization of Abadan combined cycle power plant, Indian J. Sci. Technol. 9 (2016) 7.
13 I.H. Aljundi, Aljundi, Energy and exergy analysis of a steam power plant in Jordan, Appl. Therm. Eng. 29 (2-3) (2009) 324–328.
14 O. Akbari, A. Marzban, G. Ahmadi, GholamrezaAhmadi, Evaluation of supply boiler repowering of an existing natural gas-fired steam power plant, Appl. Therm. Eng. 124 (2017) 897–910.
15 K. Thamir, A. Ibrahim, M.K. Mohammed, I. Omar, N.A. Awad, F. Abdalla, N. M. Basrawi, G. Marwah, R.M. Najafi, A comprehensive review on the exergy analysis of combined cycle power plants, Renew. Sustain. Energy Rev. 90 (2018) 835–850.
16 K.K. Dubey, R.S. Mishra, Energy-exergy analysis of combined reheating regenerative Rankine cycle using entropy generation principle, Int. J. Recent Technol. Eng. 8 (September (3)) (2019) 277–3878.
17 T. DatHoanga, D.K. Pawluskiewiczb, The efficiency analysis of different combined cycle power plants based on the impact of selected parameters, Manuscript (2016).
18 M. Ameri, P. Ahmadi, The study of ambient temperature effects on exergy losses of a heat recovery steam generator, in: International Conference on Power Engineering, October (23–27) 2007, Hangzhou, China.
19 V. Rohani, M. Ahmadi, Using double pressure heat recovery steam generator equipped with duct burner for full repowering a steam power plant and its analysis by exergy method, Int. J. Mater. Mech. Manuf. 2 (November) (2014) 4.
20 R. Kehlhofer, Combined-Cycle Gas & Steam Turbine Power Plants. PennWell Books, 2009.
21 A. Bejan, Advanced Engineering Thermodynamics, third ed., John Wiley & Sons, Inc., 2006 (All rights reserved).