74

Ushbu maqola energiya infratuzilmasining zamonaviy muammolari sharoitida o‘rta kuchlanishli taqsimlash tarmoqlaridan foydalanishning texnik-iqtisodiy jihatlarini asoslashga bag‘ishlangan. Havo liniyalari va transformator podstansiyalari asosiy parametrlarining narx ko‘rsatkichlarining approksimatsiyalangan funksiyalari asosida ideallashtirilgan tarkiblar usulini qo‘llab o‘rta kuchlanishli elektr tarmog‘ida 20 kVli kuchlanishdan foydalanishni texnik-iqtisodiy asoslash amalga oshiriladi. Bunda funksiya ekstremumining koorrdinatalarini aniqlash uchun Logranjning noaniq ko‘paytuvchilari uchuli ishlatiladi. O‘rganish uchun kuchlanishi 10(6) kV bo‘lgan elektr energiyasini uzatish uchun mo‘jallangan elektr tarmog‘ining 12 ta uchastka varianti ko‘rib chiqilgan. Olingan natijalar asosida quyidagilar aniqlandi: 10 kVli havo liniyalarining kapital xarajatlari 20 kVli havo liniyalarnikiga qaraganda 1% oraliqda bo‘ladi;simning ma’lum kesim yuzasida 20 kVli tarmoqning o‘tkazish qobiliyati 10 kVliga qaraganda 2 barobar yuqori;uzatilayotgan bir xil quvvatda quvvat va elektr energiya isrofi 4 barobar kam; tarmoq parametrlarining barcha turdagi qiymatlarida tarmoqni 10 kVdan 20 kVga o‘tkazish maqsadga muvofiq.

  • Internet havola
  • DOI10.24412/2181-1431-2023-4-40-45
  • UzSCI tizimida yaratilgan sana 15-03-2024
  • O'qishlar soni 74
  • Nashr sanasi 21-12-2023
  • Asosiy tilO'zbek
  • Sahifalar40
Ўзбек

Ushbu maqola energiya infratuzilmasining zamonaviy muammolari sharoitida o‘rta kuchlanishli taqsimlash tarmoqlaridan foydalanishning texnik-iqtisodiy jihatlarini asoslashga bag‘ishlangan. Havo liniyalari va transformator podstansiyalari asosiy parametrlarining narx ko‘rsatkichlarining approksimatsiyalangan funksiyalari asosida ideallashtirilgan tarkiblar usulini qo‘llab o‘rta kuchlanishli elektr tarmog‘ida 20 kVli kuchlanishdan foydalanishni texnik-iqtisodiy asoslash amalga oshiriladi. Bunda funksiya ekstremumining koorrdinatalarini aniqlash uchun Logranjning noaniq ko‘paytuvchilari uchuli ishlatiladi. O‘rganish uchun kuchlanishi 10(6) kV bo‘lgan elektr energiyasini uzatish uchun mo‘jallangan elektr tarmog‘ining 12 ta uchastka varianti ko‘rib chiqilgan. Olingan natijalar asosida quyidagilar aniqlandi: 10 kVli havo liniyalarining kapital xarajatlari 20 kVli havo liniyalarnikiga qaraganda 1% oraliqda bo‘ladi;simning ma’lum kesim yuzasida 20 kVli tarmoqning o‘tkazish qobiliyati 10 kVliga qaraganda 2 barobar yuqori;uzatilayotgan bir xil quvvatda quvvat va elektr energiya isrofi 4 barobar kam; tarmoq parametrlarining barcha turdagi qiymatlarida tarmoqni 10 kVdan 20 kVga o‘tkazish maqsadga muvofiq.

Русский

Данная статья посвящена обоснованию технико-экономических аспектов использования распределительных сетей среднего напряжения в условиях современных проблем энергетической инфраструктуры. На основании приближенных функций ценовых показателей от основных параметров воздушных линий и трансформаторных подстанций методом идеализированных составляющих выполнено технико-экономическое обоснование использования напряжения 20 кВ в электрической сети среднего напряжения. В этом случае для определения координат экстремума функции используются нечеткие множители Логранжа. Для исследования было рассмотрено 12 вариантов участков электрической сети, предназначенных для передачи электроэнергии напряжением 10(6) кВ. На основании полученных результатов установлено: капитальные затраты на ВЛ 10 кВ находятся в пределах 1% от затрат на ВЛ 20 кВ, пропускная способность сети 20 кВ на заданном сечении провода выше в 2 раза. чем у 10 кВ, при той же передаваемой мощности потребляемая мощность и электроэнергия в 4 раза меньше; желательно перевести сеть с 10 кВ на 20 кВ во всех видах значений параметров сети.

English

This article is devoted to the substantiation of the technical and economic aspects of the use of medium-voltage distribution networks in the context of modern problems of energy infrastructure. Based on the approximate functions of price indicators from the main parameters of overhead lines and transformer substations, a feasibility study for the use of 20 kV voltage in an average voltage electrical network was carried out using the method of idealized components. In this case, fuzzy Logrange multipliers are used to determine the coordinates of the extremum of the function. For the study, 12 variants of sections of the electric network intended for the transmission of electricity with a voltage of 10(6) kV were considered. Based on the results obtained, it was found that the capital costs of a 10 kV overhead line are within 1% of the costs of a 20 kV overhead line, the capacity of a 20 kV network at a given wire section is 2 times higher. less than 10 kV, with the same transmitted power, the power consumption and electricity are 4 times less; it is desirable to transfer the network from 10 kV to 20 kV in all types of network parameter values.

Havola nomi
1 Осинцев, К.А. Еще раз о переводе воздушных электрических сетей 6-10 кВ на напряжение 20 или 35 кВ / К. А. Осинцев, А.В. Шунтов //ЭЛЕКТРОЭНЕРГИЯ. Передача и Распределение. – 2018. - №5(50). - С. 14-16
2 Иванов, В.Е. Разработка технических решений и рекомендаций по переводу действующих сетей 6–10 кВ на напряжение 20 кВ в сельской местности // ЭЛЕКТРОЭНЕРГИЯ. Передача и распределение. –2018.- №4 (49). -С. 36 –41.
3 Абдурахманов, А.М. Принципы построения воздушных электрическихсетей напряжением 20 кВ / А.М. Абдурахманов, С.В. Глушкин, К.А. Осинцев, А.В. Шунтов // ЭЛЕКТРОЭНЕРГИЯ. Передача и Распределение. – 2019. – № 6(57). – С. 50-55.
4 Зуев, М.М. Об эффективности воздушных электрических сетей 20 кВ / М.М.Зуев, К.А. Осинцев, А.В. Шунтов // Радиоэлектроника, электротехника и энергетика. -2018. – С. 1024.
5 Миридонов, А. Перспективы развития сетей 20 кВ в ПАО «МОЭСК» / А. Миридонов, А. Ермаков // ЭЛЕКТРОЭНЕРГИЯ. Передача и распределение. – 2016. –№3. - С. 58 – 59.
6 Асташев, Д.С. Применение напряжения 20 кВ для распределительных электрических сетей России / Д.С. Асташев, Р.Ш. Бедретдинов, Д.А. Кисель, Е.Н.Соснина // Вестник НГИЭИ. – 2015. – № 4. – С. 6 – 9.
7 Гейбатов, Т. Опыт проектирования сети 20 кВ для электроснабжения отдаленных населенных пунктов в ХМАО / Т. Гейбатов // ЭЛЕКТРОЭНЕРГИЯ. Передача и Распределение. – 2013. - №6(21). – С. 70-73.
8 Майоров, А.В. О применении номинального напряжения 20 кВ в воздушных электрических сетях / А.В. Майоров, К.А.Осинцев, А.В.Шунтов // Электричество–2018.-№9.-С.4–11
9 Taslimov A.D., Raximov F.M., Raximov F.M. 0,4 kV li N ta liniyalarda elektr energiyasining yo‘qotilishlarini hisoblash dasturi // EHM uchun dastur № DGU № 20534.
10 Таслимов А.Д., Юлдашев А.А. Разработка технико-экономических моделей элементов систем электроснабжения // Проблемы энерго- и ресурсосбережения. Ташкент, 2022.-№1.-С.62-65
11 Таслимов А.Д. Развитие теории и методов выбора параметров городских распределительных электрических сетей в условиях неопределенности: Монография.Т.: ТашГТУ, 2020. 216 с.
12 Карапетян, И.Г. Справочник по проектированию электрических сетей/ И.Г.Карапетян, Д.Л.Файбисович, И.М.Шапиро; под ред. Д. Л. Файбисовича. –4-е изд., перераб. и доп.– М.: ЭНАС, 2012. – 376 с.
13 СТО 34.01–21.1–001–2017 Распределительные электрические сети напряжением 0,4-110 кВ. Требования к технологическому проектированию. М.: ПАО «Россети», 2017.– 233 с.
Kutilmoqda